Home > Error Code > Triton Atm Error Code 236

Triton Atm Error Code 236

Contents

Test the dispenser by completing several test dispenses. Verify that the power supply is operating and the DC voltages being supplied to the main board and dispenser are correct. Refer to error 500. 514 SPED device bit stuck. Clear terminal error code. navigate here

Clear the error. 5. Inspect electronic journal to dispenser communication cable for damage. Inspect the printer data cable for damage. Refer to error code 535. 543 Card Reader ñ Sequence error.

Triton Error Code 244

If these actions have no effect, replace the dispensing mechanism. 49 Jam at exit This status is generated when exit sensor is blocked.1 Inspect the feed path for jammed currency. Restart the operating system. Make sure the connectors are seated securely on the main board and on the electronic journal. 2.

  • This error code is produced when the single reject event counter exceeds 50 reject events or the bundle reject event counter exceeds 250 notes.
  • Replace the dispenser is the error persists. 366 Dispenser cassettes disabled.
  • The system returned: (22) Invalid argument The remote host or network may be down.
  • This can be confirmed by referencing the electronic journal.
  • Doing this will not clear any available memory, and will not aid in clearing Error Code 151.) Below are steps to take to clear Error code 151 on 32-bit machines: 1.
  • Facebook Facebook LinkedInSearch Access © 2016: Access ATM, All Rights Reserved Access ATM, Inc.
  • Inspect the feed path for currency that is stuck together or jammed.
  • Refer to error 500. 516 SPED device no attention Refer to error 500. 517 SPED device timeout.

Replace the dispensing mechanism. 52 RAM error A mechanical failure has occurred. If the cables are undamaged, the main board or electronic journal may be defective 149 Read from electronic journal failed 1. Once you have completed one of the above(more…) 152 Electronic journal corrupt 1. Mitsubishi Triton Error Codes Restart the cash dispenser.

Check the dispenser data and power cable connections. Atm Error Codes List The reject vault should be emptied as soon as possible in order to avoid an ìOut of Serviceî condition that occurs when the number of reject events reaches 50. If these actions have no effect on dispenser operation; replace the dispenser mechanism. 128 Error in reply from the dispenser mechanism Inspect cable from the Backplane to the Electronic Journal to http://www.atmdepot.com/triton-atm-error-codes/ Do several test dispense operations. 4.

Inspect the note qualifier for any damage (i.e. Triton Atm Error Code 101 Examples of this are two move commands sent one after another or a deliver command that is sent without a previous move command. Otherwise, the possible causes of the problem may be a defective paper low sensor, cable, docking assembly or. This error code is generated when there is a checksum error in data stored in the note cassette.

Atm Error Codes List

Refer to error code 535. 556 System timeout. https://www.nasatm.com/error_codes/P320/ If the power supply if operating normally; replace the note qualifier to correct the problem. 325(49h)[I] Note qualifier faulty Error code 325 is generated when the double detect sensors in the Triton Error Code 244 Inspect the dispensing mechanism for jammed currency at the diverter. Triton Error Code 151 Seat connectors or replace the power supply as needed. 2.

This page uses frames, but your browser doesn't support them. 800.498.5795 New! check over here Clear terminal error code. Complete several Test Dispenses to verify correct operation. If it works with the door open, remove obstruction causing the diverter to contact the vault door. 4. Atm Error Code 3-da000(80)

Your cache administrator is webmaster. This error code occurs while running the dispenser on the NMD test software and when too many notes are requested during a dispense command. If any sensor is out of its calibration limits; clean all of the sensors and attempt to do a transaction. http://u2commerce.com/error-code/triton-atm-error-code-148.html Make sure the connectors are seated securely on the main board and on the electronic journal. 2.

Remove and refill the affected cassette using normal replenishment procedures. 303(33h)[3] Lifts are down. Triton Traverse Error Code 917 Inspect for jammed currency in the feed path and at the Exit sensor. Reset the cash dispenser and clear the error.

If error persists; replace the main board assembly. 557 System device reset.

Replace the dispenser. 53 (35h) EPROM error A mechanical failure has occurred. This will occur if the machine is switched off and on during normal daily operation. If the problem persists, replace the dispensing mechanism 100 Good operation No Action Necessary. Atm Error Codes 072 If error persists; replace the dispenser mechanism. 372 Dispenser item value error Clear terminal error code.

Test the dispensing mechanism by completing several Test Dispenses. 3. Refer to error 522. 530 EJ EXT error. Purge the dispenser using the purge command. http://u2commerce.com/error-code/triton-atm-error-code-110.html If error fails to reset, or the error reoccurs in a short amount of time, consider replacing the SPED. 241 SPED Warning: Self Test error See Error Code 240 382 Dispenser

Test the dispenser by completing several test dispenses. 5. Restart operating system. This is a Triton Connect error. Purge the dispensing mechanism with the PURGE command from the DIAGNOSTICS function.

for a four cassette dispenser. Otherwise; replace the dispensing mechanism. 110 (6Eh) Trailing edge time-out at exit. 1. If the status clears and the return code are normal place the cash dispenser in service. Verify the blue lever on the left side of the printer in the print position.

Inspect electronic journal to dispenser communication cable for damage. If present; ìunlockî and remove each cassette from its feed channel. Place all belts on their respective rollers and gears. If problems still persist, replace the dispenser mechanism and/or the note cassette.

All Rights Reserved.

GplusFacebookTwitterYoutubeRssMailATM Sales & Processing: 888-959-2269 Home About Us Make More Money Customers Comments How ATMs Work ATM Processing Get Started How You Make Money How Much You If the cash dispenser operates normally put it back in service. If excessive rejects are suspected, see corrective action for Error Code 48. 3. Test the dispensing mechanism by completing several test dispenses.

Use a soft brush abd vacuum cleaner to clean the exit sensor. 4. Download to Triton Connect. If the error clears; put the cash dispenser in service. 4. If error persists; replace the dispenser mechanism. 369 Dispenser device reset.

Check if communication cable or com port is not connected (Check out our Hyosung ATMs for sale & our Triton ATMs for sale) Error 2YY15 Hyosung ATM Error Code When performing a "purge" or "test dispense" operation the return code will be "0" in the first digit returned by the dispenser. Attempting to operate the cash dispenser without the reject vault will normally cause it to go to an ìOut of Serviceî condition.