Home > Error Code > Triton Rl5000 Error Codes

Triton Rl5000 Error Codes

Contents

Verify that the diverter moves freely and is not binding. Inspect the feed path for any jammed notes. Inspect the cassette and feed path for jammed currency. Reset the cash dispenser and clear the error. http://u2commerce.com/error-code/triton-atm-error-codes-pdf.html

Replace the dispenser if the error persists. 167 Reported low cash to Triton Connect This is an indication that the cash in the cassette has gone below the threshold level set If the voltages are correct, and the cables are undamaged and correctly connected, causes of this error may be a defective cable, a defective printer, printer control board, or the main Verify that all access panels are closed and secured. The dispenser sends this status code when a command has been successfully executed. my site

Triton Error Codes

Turn the AC power OFF for a few seconds and then back ON to power cycle and reset the cash dispenser. Restart ATM. Refer to error code 535. 544 Card Reader ñ Invalid request.

  1. If these actions have no effect; replace the dispenser. 44 (2Ch) Bad roller profile / Double Detect Error A mechanical failure has occurred.
  2. Inspect electronic journal to dispenser communication cable for damage.
  3. However; actions to fill the cassette should be taken as soon as possible. 302(32h)[2] Empty Cassette.
  4. Verify that the diverter moves freely.
  5. If the journal prints successfully; verify that all records were audited by performing the Print Journal function again.
  6. Purge the dispenser using the purge command.
  7. Restart the cash dispenser.

This error code is generated when a document from a note feeder fails to reach the note qualifier with in a specified time. Replace the dispenser. 53 (35h) EPROM error A mechanical failure has occurred. If the error persists; replace the Electronic Journal. 194 An attempt to dispense bills has been made when the cassettes are unlocked. Triton Error Code 139 Replace SPED battery is below 2.8 VDC.

Purge the dispenser with the purge command under diagnostics. Triton Atm Error Code 33 The error code will be sent to the Triton Connect host if Triton Connect feature is enabled. Refer to error 500. 505 SPED device busy. Note: Dispenser Status (Click Counts) should be run and available before contacting Tech Support 106 FIFO error The dispensing mechanism may have corrupt software.

Clear all errors and test the dispenser by completing several TEST DISPENSES. Mitsubishi Triton Error Codes If the error clears, put the cash dispenser in service. 4. Reset the cash dispenser and clear the error. If error fails to reset, or the error reoccurs in a short amount of time, consider replacing the SPED. 241 SPED Warning: Self Test error See Error Code 240 382 Dispenser

Triton Atm Error Code 33

Complete a live transaction. http://atmequipment.com/s.nl/it.I/id.20/.f If the voltages at PL2 are incorrect; check all pins on cable 09600-00013 for continuity from end-to-end. Triton Error Codes If there is no visible damage and the connectors are attached to the sensor boards the best course of action is to replace the dispensing mechanism. Triton Error Code 244 All rights reserved.

Clear the error. weblink Inspect the dispensing mechanism for jammed currency at the exit sensor. If the cable ends are seated properly and there is no apparent damage to the cable; replace the CPU Module. 1. If the test dispenses are completed normally, and the return code are correct, clear all errors and place the cash dispenser in operation. 5. Triton Error Code 151

If the error clears, put the cash dispenser in service. 6. If the error clears; put the cash dispenser in service. 3. If the problem persists, replace the dispensing mechanism. 135 Feed sensor blocked as reported by status check 1. navigate here This error occurs when the logical sequence of the commands sent to the dispenser is not the one expected by the system.

Inspect for jammed currency at the diverter. Triton Error Code 246 Use a soft brush and vacuum cleaner to clean the exit sensor. 4. Look up the definition on the Hardware Status listing. 4.

If the error clears put the cash dispenser into service.

Restart the operating system. a. Test the dispenser by completing several test dispenses. 4. Triton 9100 Error Code 148 See error code 557. 562 SPED error.

Inspect main board to electronic journal communication cable for damage. Turn the AC power OFF for a few seconds and then back ON to power cycle and reset the cash dispenser. Make sure the connectors are seated securely on the main board and on the electronic journal. 2. his comment is here If it is necessary to check continuity of the cable assembly, refer to Appendix B for pin out of the cable assembly 5.

If the cable ends are seated properly and there is no apparent damage to the cable; it will be necessary to verify the continuity of each cable; otherwise replace the dispenser. If the cables are undamaged, the main board or electronic journal may be defective 150 Status command to journal failed 1. Inspect main board to electronic journal communication cable for damage. Reset the cash dispenser.

If the error clears put the Cash Dispenser into service. Formlabs et.